Valley Gutter

Specify the lineal footage of valley gutter for the entire building, and the number of conductor heads. Be aware that the conductor heads specified are NOT downspout sleeves. They are actual conductor heads (See picture below)

 

Valley gutter is 14ga pre-galvanized.

 

NOTE: Interior drains are needed.  These interior drains are not by Manufacturer.  You should specify the spacing and size of interior drains on a sketch or in the Notes section of the contract.

 

Manufacturer will furnish standard light-gauge conductor heads when requested.

 

Provide sketch and detail indicating exact valley gutter locations in project.  Also provide details and exact valley or parapet gutter size requirements.

 

Click to Enlarge Image